Key Operational Controls for Ultrafiltration as Pretreatment for Reverse Osmosis

Backwash frequency, air scour intensity, and the cycle for chemical-enhanced backwashing are the three key control points for stable ultrafiltration pretreatment operation.

Key Operating Control Points for Ultrafiltration Membranes as Pretreatment for Reverse Osmosis | Article Illustration

Why choose ultrafiltration over traditional filtration

The nominal pore size of the ultrafiltration membrane is in the range of 0.03 μm. It provides stable retention of colloids, microorganisms, and large organic molecules, typically keeping the effluent SDI15 within 3. Compared to sand filtration, it better accommodates water quality fluctuations and reduces fouling risks in the reverse osmosis stage.

Three Key Points of Run Control

Backwash Frequency: Set based on the rate of transmembrane pressure increase; reduce the interval when water quality is poor. Use ultrafiltrate as backwash water to avoid introducing new particles.

Air scouring intensity: Air-water backwashing significantly improves the removal of fouling layers from fiber surfaces, but excessive air volume can damage the fibers. Control air flow according to component specifications.

Chemically Enhanced Backwash and Chemical Cleaning: Periodic dosing of low-concentration chemicals controls organics and microorganisms; chemical cleaning is scheduled when transmembrane pressure reaches the set threshold.

Common Runtime Issues Troubleshooting

Continuous decline in permeate flow with low differential pressure usually indicates membrane fouling or temperature changes. Rapid increase in differential pressure typically results from particulate matter in the feed water or excessive coagulant dosage. Abnormal permeate turbidity requires inspection of membrane fiber integrity and end-cap sealing. When anomalies are detected, perform an integrity test first before deciding whether to replace the module.

This document serves as a technical reference. Final selection and operating parameters must be determined based on actual project water quality, temperature, and system configuration. Product specifications are subject to the manufacturer's latest technical documentation.
Consultation

Get Product Recommendations

Provide the raw water analysis report and permeate requirements; our technical team will recommend the appropriate membrane type and calculate the required number of elements.

Contact the technical team directly

Submit your raw water analysis report and permeate requirements. You may contact us via phone or WeChat; our technical team will provide recommendations on membrane type selection and element quantity calculation.

LITONG Technology WeChat Customer Service QR Code, WeChat ID: 134 1851 5855

Scan QR code to add on WeChat

Guangdong ICP License No. 2025494771-1